百能 百能
Focus on global challenges and pressures, provide competitive energy and environmental solutions and services, and continuously create maximum value for customers.
Project Background
A dedicated alkali-recovery incineration system is provided to treat upstream concentrate with a solids content of 50–70%. The single furnace processes 15 t/h. High-temperature incineration safely destroys the organic-rich concentrated waste liquid while recovering its energy as high-quality superheated steam at 9.8 MPa(g) and 360°C, turning waste into a resource.

Technical Characteristics

Self-sustaining energy design uses waste liquid as fuel.

1. The concentrate's own high calorific value supplies the main fuel; natural gas is used for auxiliary firing, startup and shutdown.

2. Rated steam output is at least 50 t/h per furnace. The operating range is 50–110%, providing strong load flexibility.

3. The system accommodates boiler-feedwater temperatures of either 148°C or 220°C. Adjusting natural-gas consumption maintains rated steam output.

Solution

Integrated ultra-low-emission control addresses multiple pollutants.

1. A pre-combustion chamber and low-NOx burners ensure complete destruction of organics. Specific organic pollutants and non-methane hydrocarbons must meet the stringent limits of GB 31571-2015 and Beijing local standard DB11/447-2015.

2. Flue gas is treated by a bag filter and low-temperature selective catalytic reduction (SCR), with stack-outlet CEMS monitoring. PTFE filter bags with PTFE membranes and 2205-grade bag cages ensure outlet dust at or below 5 mg/Nm³.

The emissions guarantee simultaneously satisfies project-specific requirements and both cited standards, supporting first-pass environmental acceptance. Guaranteed limits are particulate matter ≤5 mg/Nm³, NOx ≤35 mg/Nm³, SO₂ ≤35 mg/Nm³, non-methane hydrocarbons (VOCs) ≤20 mg/Nm³ and dioxins ≤0.1 ng-TEQ/Nm³.

Project photograph

Get The Effect

Capacity per furnace: 15 t/h of concentrate with 50–70% solids. Operating range: 50–110%. Steam output: at least 50 t/h at 9.8 MPa(g) and 360°C. Guaranteed boiler efficiency on a lower-heating-value basis: at least 83.8%.
Copyright © 2026 Pyneo Co.,Ltd. All Rights Reserved. 浙ICP备20004608号-2 Sitemap