Focus on global challenges and pressures, provide competitive energy and environmental solutions and services, and continuously create maximum value for customers.
Project Background
The project adds a 200 t/h multi-effect evaporation unit to treat high-salinity wastewater from the PTA plant. Its central innovation is to use low-grade heat in organic vapor discharged from the main unit's dehydration-column overhead as the principal heat source, coupling waste treatment with energy recovery. Annual stable operation is designed for at least 8,400 hours, and core process equipment has a design life exceeding 20 years.

Technical Characteristics

Cascaded waste-heat use: Organic vapor at 85°C supplies heat that is reused successively through the evaporation effects.

Combined modular evaporators: Forced-circulation, falling-film and other configurations are selected to match viscosity, boiling-point elevation and scaling tendency at each stage, balancing efficiency and operating stability.

Carryover prevention: High-efficiency combined wire-mesh and baffle demisters use spray washing and periodic high-flow chemical cleaning. Condensate sodium concentration remains below 10 ppm for high-quality reuse water.

Automated control: The DCS regulates feed, temperature, pressure, vacuum, pH and density. Two-stage pH control combines coarse adjustment in the feed tank with fine adjustment upstream of the feed pump.

Load flexibility: The source specifies an operating range of 0–120% to cope with upstream fluctuations.

Water reuse: Qualified condensate enters the site's reuse-water network; off-spec water returns to the feed tank in a closed loop.

Solution

Heat-source integration: Mixed vapor from the PTA dehydration-column overhead contains approximately 62–65% IBA, 22–25.7% water and 9–12% MA. Flow is about 420–450 t/h at 85°C. After heat exchange through the multi-effect unit, the organic liquid is cooled to 40°C and returned to the original column, recovering both heat and material.

Multi-effect evaporation and concentration: High-salinity wastewater initially containing about 4% salts is progressively concentrated to a slurry with 50% solids, adjustable to downstream disposal requirements.

Project photograph

Get The Effect

Rated wastewater treatment: 200 t/h; the performance section specifies a 60–120% operating range. Feed concentration increases from 4% to an adjustable 50%, monitored precisely by an online density meter. The heat source supplies 420–450 t/h of mixed vapor at 85°C and 10 kPa(g). Steam consumption is approximately zero at rated conditions because the process relies mainly on waste heat. Reuse-water sodium is below 10 ppm. Annual operation is at least 8,400 hours, with availability above 96%, and service life is at least 20 years. The system is designed for long-term, stable and efficient operation under the specified conditions, delivering continuing energy, water and environmental benefits.