百能 百能
Focus on global challenges and pressures, provide competitive energy and environmental solutions and services, and continuously create maximum value for customers.
Project Background
The boilers originally used SNCR denitrification. To meet increasingly stringent environmental requirements, a new SCR system is installed in the rear flue, the existing SNCR system is optimized, and the economizer design is replaced. The retrofit delivers compliant emissions and strong load adaptability.

Technical Characteristics

No space had been reserved for SCR reactors in the rear boiler flues. The economizers therefore require rearrangement to create space for built-in SCR reaction modules.

Solution

The project adds an SCR system and auxiliaries, designs and replaces the upper and lower economizers with integrally extruded spiral economizer structures, and rearranges associated systems to provide the required clearance and temperature window for the SCR reactor. The existing SNCR system is optimized, controlling aqueous-ammonia injection to prevent excessive ammonia slip.

Project photograph

Project photograph

Project photograph

Get The Effect

Across 50–100% BMCR boiler load, NOx is ≤30 mg/Nm³ and ammonia slip is ≤2.5 mg/Nm³.