百能 百能
Focus on global challenges and pressures, provide competitive energy and environmental solutions and services, and continuously create maximum value for customers.
Project Background
The project provides SNCR denitrification for 2 × 750 t/day municipal solid waste incinerators. It removes nitrogen oxides from incineration flue gas to outperform GB 18485-2014, Standard for Pollution Control on Municipal Solid Waste Incineration.

Technical Characteristics

The original fuel has a high nitrogen content. Proprietary denitrification lances ensure effective reducing-agent atomization and spray coverage.

Solution

Bagged urea is manually emptied into a dissolution tank. Water and urea are mixed with agitation and steam heating to accelerate dissolution. Valves control water and urea feed to achieve the required solution concentration. A transfer pump sends the prepared solution to storage. It is then pumped to a static mixer, diluted with water and delivered to the furnace injection system. Pneumatically atomized SNCR lances have quick connections for urea, atomizing air and cooling air, each linked by metal hose to its corresponding pipeline. Lances are installed within the appropriate furnace temperature window to ensure thorough mixing and reaction.

Project photograph

Project photograph

Get The Effect

The system is designed for initial NOx of 400 mg/Nm³ at maximum load, on a dry standard basis corrected to 11% oxygen. Outlet NOx is below 150 mg/Nm³ and ammonia slip below 8 mg/Nm³ on the same basis, outperforming the NOx requirements of GB 18485-2014.
Copyright © 2026 Pyneo Co.,Ltd. All Rights Reserved. 浙ICP备20004608号-2 Sitemap